Pipeline anti-corrosion Tape

Primer for Cold Applied Tape

Primer for Cold Applied Tape
Primer for Cold Applied Tape
DQ series of primer for cold applied tape is is made up of butyl rubber, unsaponifiable resins, tackifier, stabilizer, and solvent.

*Unit:kg
*Temperature:60℃

DQ series of primer for cold applied tape is is made up of butyl rubber, unsaponifiable resins, tackifier, stabilizer, and solvent.

PRODUCT DESCRIPTION

1.Introduce

     DQ series of primer for cold applied tape is is made up of butyl rubber, unsaponifiable resins, tackifier, stabilizer, and solvent.The primer is applied to the appropriately prepared pipe surface before application of anti corrosion tape. It is used for improving sealing and between the anti corrosion tape and the steel pipeline. Primer can be applied by hand brush or machine. Hand application app. 0.2 litre/m2 pipe surface. Machine application: app. 0.15 litre/m2 pipe surface. Similar to Polyken liquid adhesive systems P19, P27 Primer are flammable mixtures. 

2.Technical Data

Property

Unit

P19

P27

Solid content

%

19

27

Density

Kg/liter

0.78

0.82

Viscosity+23 ºC 
(Out flow time, 4mm nozzle)

Sec

40±5

43±5

Flash point

ºC

10-15

15-20

Drying time

Min

5-10

10-15

Dry Thickness

Mils

2.0

2.5

Color

 

Black

Black

Application temperature

ºC

-34 to 85

-34 to 85

Maximum temperature

ºC

-40 to 80

-40 to 80

Package

L

10,20

10,20

Please contact us for more details

 