Heat shrink Tubing & cold shrink Tubing

10KV Heat Shrink Cable Accessories

10KV Heat Shrink Cable Accessories
10KV Heat Shrink Cable Accessories
10kv heat shrink cable termination and joints kits widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

*Unit:PC
*Temperature:125℃
*Voltage:10kv
*Color:black,red
*Size Range:25-400mm2

10kv heat shrink cable termination and joints kits widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

PRODUCT DESCRIPTION

1.Introduce

10KV heat shrink power cable terminations and joints are consist of anti-tracking tube,heat shrink protected tube,breakout,rain shed and stress control tube,widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

2.Technical Data

Property

Test Method

Result

1min Power frequency test

45kV 1min no flash over,no strick

 no flash,no strick no flash over

Partial discharge test

The magnitude of discharge at 13kv shall not exceed 20pc

The magnitude of the discharge of the combination sample didn't exceed 2pc at 13kv

 Cyclic load test

5h heating,conduction 

temperature 95℃,3h colling

Subjected to 3 time

 Cyclic load test

Impulse voltage withstand test

Neither breakdown nor  flashover shall occur at 10 positive and negative  impulses of 105kv

No breakdown nor flashover occurred on the combination sample at 10 positive and 10 negative impulses of 105kv

DC negative polarity voltage withstand for 15min

Neither breakdown nor flashover shall occur at 52kv for 15 min

No breakdown nor flashover occurred  on the combination samples at 52kv for 15 min

4h Power frequency test

35KV 4h no flash over,no strick

 no strick,no flash over

 

3.Size and Type

Size

Type

Cable Range

10kv NRSY -3/1

 

INDOOR TERMINATION FOR 

10kv 3 CORES CABLE

25-50mm2

10kv NRSY -3/2

70-120mm2

10kv NRSY -3/3

150-240mm2

10kv NRSY -3/4

300-400mm2

10kv WRSY -3/1

 

 OUTDOOR TERMINATION FOR 

10kv 3 CORES CABLE

 

25-50mm2

10kv WRSY -3/2

70-120mm2

10kv WRSY -3/3

150-240mm2

10kv WRSY -3/4

300-400mm2

10kv JRSY -3/1

 

STRAIGHT THROUGH JOINT
FOR 10kv 3 CORES CABLE

25-50mm2

10kv JRSY -3/2

70-120mm2

10kv JRSY -1/3

150-240mm2

10kv JRSY -1/4

300-400mm2

10kv NRSY -1/1

 

INDOOR TERMINATION FOR 

10kv SINGLE CORE CABLE

25-50mm2

10kv NRSY -1/2

70-120mm2

10kv NRSY -1/3

150-240mm2

10kv NRSY -1/4

300-400mm2

10kv WRSY -1/1

OUTDOOR TERMINATION FOR 

10kv SINGLE CORE CABLE

25-50mm2

10kv WRSY -1/2

70-120mm2

10kv WRSY -1/3

150-240mm2

10kv WRSY -1/4

300-400mm2

10kv JRSY -1/1

STRAIGHT THROUGH JOINT
FOR 10kv SINGLE CORE CABLE

25-50mm2

10kv JRSY -1/2

70-120mm2

10kv JRSY -1/3

150-240mm2

10kv JRSY -1/4

300-400mm2