Product Center

News

Cold applied tape is widely used in oil and gas pipeline anti-corrosion fields.
There are a variety of factors at play. Here are a few in not particular order o...
I have used both hot(heat shrinkable sleeves) and cold applied bitumen based wra...

FAQ

Black,Red,Green,Yellow,Blue,White,Clear color heat shirnk tube
the diffrences bettwen cold applied tape and anti-corrosive tape.
the diffrences bettwen heat shrinkable tubular sleeves and heat shrinkable warpa...

Tags

Contact Us

 Adress: Meiyan,Wujiang,Suzhou,Jiangsu,China
 Tel: +86-512-63672926
 Fax:+86-512-63672818
 Email:jimmy@heatshrinkfactory.com
Email:tongjinpoly@gmail.com
Whatsapp:+86-13913054439
 Skype:tongjinpoly

Heat shrink Tubing & cold shrink Tubing

10KV Cold Shrink Cable Accessories

10KV Cold Shrink Cable Accessories
10KV Cold Shrink Cable Accessories
10kv cold shrink cable termination and joints kits widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

*Unit:PC
*Temperature:125℃
*Color:grey
*Size Range:25-630mm2

10kv cold shrink cable termination and joints kits widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

PRODUCT DESCRIPTION

1.Introduce

10KV cold shrink power cable terminations and joints are consist of cold shrink tube,cold shrink termination,cold shrink joint and cold shrink breakout,widely used in electricity supply systems under 10kv in oil refinery,metallurgy, railway, ports and other area.

2.Technical Data

Property

Test Method

Result

1min Power frequency test

45kV 1min no flash over,no strick

 no flash,no strick no flash over

Partial discharge test

The magnitude of discharge at 13kv shall not exceed 20pc

The magnitude of the discharge of the combination sample didn't exceed 2pc at 13kv

 Cyclic load test

5h heating,conduction 

temperature 95℃,3h colling

Subjected to 3 time

 Cyclic load test

Impulse voltage withstand test

Neither breakdown nor  flashover shall occur at 10 positive and negative  impulses of 105kv

No breakdown nor flashover occurred on the combination sample at 10 positive and 10 negative impulses of 105kv

DC negative polarity voltage withstand for 15min

Neither breakdown nor flashover shall occur at 52kv for 15 min

No breakdown nor flashover occurred  on the combination samples at 52kv for 15 min

4h Power frequency test

35KV 4h no flash over,no strick

 no strick,no flash over

 

3.Size and Type

Size

Type

Cable Range

10kv NLY -3/1

 

INDOOR TERMINATION FOR 

10kv 3 CORES CABLE

25-50mm2

10kv NLY -3/2

70-120mm2

10kv NLY -3/3

150-240mm2

10kv NLY -3/4

300-400mm2

10kv NLY -3/5

500-630mm2

10kv WLY -3/1

 

OUTDOOR TERMINATION FOR 

10kv 3 CORES CABLE

25-50mm2

10kv WLY -3/2

70-120mm2

10kv WLY -3/3

150-240mm2

10kv WLY -3/4

300-400mm2

10kv WLY -3/5

500-630mm2

10kv JLY -3/1

 

STRAIGHT THROUGH JOINT
FOR 10kv 3 CORES CABLE

25-50mm2

10kv JLY -3/2

70-120mm2

10kv JLY -1/3

150-240mm2

10kv JLY -1/4

300-400mm2

10kv JLY -1/5

500-630mm2

10kv NLY -1/1

 

INDOOR TERMINATION FOR 

10kv SINGLE CORE CABLE

25-50mm2

10kv NLY -1/2

70-120mm2

10kv NLY -1/3

150-240mm2

10kv NLY -1/4

300-400mm2

10kv NLY -1/5

500-630mm2

10kv WLY -1/1

 

OUTDOOR TERMINATION FOR 

10kv SINGLE CORE CABLE

25-50mm2

10kv WLY -1/2

70-120mm2

10kv WLY -1/3

150-240mm2

10kv WLY -1/4

300-400mm2

10kv WLY -1/5

500-630mm2

10kv JLY -1/1

 

STRAIGHT THROUGH JOINT
FOR 10kv SINGLE CORE CABLE

25-50mm2

10kv JLY -1/2

70-120mm2

10kv JLY -1/3

150-240mm2

10kv JLY -1/4

300-400mm2

10kv JLY -1/5

500-630mm2